SUGAR VALLEY
Referencia: 000CS0005
enjoy a pool crystal-clear and Healthy without effort. With the salt chlorinator Sugar Valley Aquascenic, you can olvidarte of the chemical products aggressive and enjoy a swimming safe and refreshing. Our system, basado in three method of disinfection naturales, ensures a clean water and transparent during all the year.
The new equipment of electrolysis of low salinity + Hydrolysis + Ionization Aquascenic uses three method of disinfection to obtain thus a perfect Sterilisation of water, without the need to add no product chemical.
The hydrolysis rompe the molécula of water generating thus agents of disinfection a base of oxygen (OR³, OR², OH...). The electrolysis USA the cloruros present in the water (not needs add salt) for producir HClO (desinfectant). As tercer system of disinfection uses the ionization of copper and plata, produciendo a effect algicida, Bactericidal and flocculant for producir a desinfectant residual.
With the new equipment of Hydrolysis + Ionization + electrolysis of Aquascenic LOW SALT will have a comprehensive solution for treat the water with every effectiveness.
Vamos a exponerle the principios of operation of the equipment of Electrolysis of low salinity + Hydrolysis + Ionization "AQUASCENIC".
The water is compuesta of 2 parts of hidrógeno and 1 part of oxygen (H2OR).
Hydrolysis significa etimologicaly descomposition for the water. The hydrolysis is a Process for Generate hidrógeno and oxygen for medio of the electricity and the water. To The pasar a flow electrical via water rompe the coupling chemical, the cargas negative or iones of oxygen emigran to the electrode positive (ánodo). The iones of hidrógeno, that are carged positivaly, are atraídos for the electrode negative (cátodo). The descomposition that producirá will be the siguient:
Energy electrical + 2 H²OR? 2 H² + OR²
This da as result a element negative extra, as in the combination of the number of electrones exceeds in 1 to the protones. Ahora is a unique hidróxido carged negativaly, or a ion of hidróxido (OH -). In the Hydrolysis existen numerous reagents chemicals secundary, that also producen especies iónicas with a poder oxidant and desinfectantes as the ozono (OR²), oxygen monoatómico (OR1) and peróxido of hidrógeno (H²OR²).
The circuit electronic of our box electronics Transform the flow (220 V, 50Hz) in flow continuous of a low voltage and a high amperaje. This flow will be supplied a some electrodos of titanium actived with metales nobles coloced in the recirculation of water in a support especially designed for tal fin. In these electrodos not solubles creates a combination of it more poderous oxidantes existentes for the disinfection of water preventing thus the use of chemical products.
If in this treatment incorporamos a small quantity of salt between 1 and 2 gr of salt for litre of water well whether for falta of conductivity or for querer Generate a residual tangible, conseguiremos thus which same system in addition to Generate a residual of chlorine for electrolysis salina a low concentration. The products descomponen, act and vuelven a regenerar. The desinfectant residual genered for the electrolysis not perjudicará to the eyes, the skin ni to the salud of the swimmers.
Not will have that preocuparse if its pool queda without salt as the system seguiría desinfectando in of Hydrolysis. The chlorine genered Destroys the materia organic and pathogens present in the water transformándose nuevaly in cloruro sodium (salt common).
The use assembly of copper and plata, ambos with altas capacities of disinfection, aumenta enormely the effectiveness of each one of our systems, if in addition to eso in the case of water cold apoyara with the presence of a thirdly that whether combinable (chlorine), the progresion desinfectant is geométrica.
The aportation of metales to the water as desinfectantes has venido usando from hace muchísimos years from the cultura griega pasando for the edad media, even in América, during the colonization of the antiguo oeste, also introducía a dólar of plata in the barriles of water. Actually añaden iones of plata a bebidas tan usuales as cervezas, licores and vinos.
The reaction productora of iones (in the ánodo):
Cu++? Cu²+ + 2e- Ag++? Ag+ + 1e-
| DESCRIPTION | HD 1 | HD 2 | HD 3 |
| unit ELECTRÓNICA | |||
| Intensity | 0 - 100 % | ||
| Salinity | From 1,5 g up to 100 g NaCl/l | ||
| m³ pool (< 28ºC) | 65 m³ | 100 m³ | 200 m³ |
| m³ pool (> 28ºC) | 40 m³ | 80 m³ | 125 m³ |
| Display | 2,8" TFT full colour extraible (12 idiomas) | ||
| Alimentation | 220 V 50/60 Hz | ||
| Outlet | 8-8 A | 8-15 A | 8-20 A |
| Consumption maximum | 80 W | 120 W | 160 W |
| Dimensions | 270 x 220 x 115 mm | ||
| unit electronics | Plastic ignífugo ABS black | ||
| Lid protection | Plastic ABS grey | ||
| Control | Microprocesador 32 bits | ||
| Regulation intensity | Amperaje + Voltage | ||
| Ventilation | Disipador | ||
| Autolimpieza | Programable of 1 a 24 hours | ||
| Control of flow | Sensor of gas | flow sensor rate | |
| Contador of hours | Yes, Accessible for cliente | ||
| Control of production | of 0 a 100% | ||
| Alarmas | low conductivity / Falta of flow / pH dosificando / pH excesive outside of range / pH maximum time dosing | ||
| Test salinity | Detecta g/l of salt (Precision of ± 10%) | ||
| Control production to cover | Configurable level production 0-100% dependiendo of cover pool abierto or closed | ||
| Production for signal externa | Configurable level production 0-100% dependiendo of any signal externa (segunda inlet analogue) | ||
| Comunications | MODBUS RS485 / WiFi / ETHERNET | ||
| Outlets of control main | Control of filtration / Control lighting / Control of Heating | ||
| Outlets of control additional | 4 salidas of relay additional configurables for the usuario | ||
| CELL electrolysis SALINA | |||
| Cell electrolysis salina | 5 panels of titanium | 7 panels of titanium | 10 panels of titanium |
| minimum flow rate | 5 m³/h | 9 m³/h | 11 m³/h |
| Medidas panels | 200 x 45 mm | 200 x 45 mm | 400 x 45 mm |
| material support cell | Plastic PVC transparent | ||
| seal cell | threaded for easy montaje of cell | ||
| Diameter connection pipe | 63 mm | ||
| Cable cell | (3 x 4) x 1,5 m | ||
| Sensor of gas | included in cell | NOT | |
| Maximum pressure | 4 Kg/cm² | ||
| Temperature maximum | 45ºC | ||
| VASO OF IONIZATION | |||
| Number of electrodos | 2 | 4 | 6 |
| Dimensions (length/Ø) | 177 x 141 mm | 280 x 141 mm | 400 x 141 mm |
| Connection | thread 2" (63 mm) | ||
| material of the pool shell | ABS transparent | ||
| material of the electrodos | Copper and plata electrolitic | ||